2.16
Climaveneta’s range of small to medium sized i-NX Cooling Only chillers efficiently and easily
i-NX
adapt to a wide range of cooling capacities.
With the exclusive 1 + i philosophy, both the fixed speed scroll compressor and the scroll inverter compressor are combined in the
Air Cooled Chiller
same circuit. This technology ensures maximum benefit in terms of efficiency at partial loads compared to a solution with separate
circuits. In different load conditions, only the most efficient combination of compressors required for optimum adaptation to the
(43.9-129kW)
system load conditions is called upon.
Cooling Only
Key Features
High Efficiency - inverter driven scroll compressor
Available with EC fans
Aluminium microchannel coils
ERP 2021 compliant
Three Phase
Wide operating range
Available with hydronic module
MODEL
i-NX 0151P
i-NX 0182P
i-NX 0202P
i-NX 0262P
i-NX 0302P
i-NX 0352P
i-NX 0402P
i-NX 0502P
POWER SUPPLY
V / ph / Hz
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3/50
400/3/50
PERFORMANCE
COOLING CAPACITY *1
kW
43.9
52.9
63.1
72.1
83.8
101
120
129
TOTAL POWER INPUT *1
kW
15.7
18.8
21.4
25
29.2
35.2
41.9
46.8
EER *1
2.8
2.81
2.95
2.88
2.87
2.87
2.86
2.76
ESEER *1
4.56
4.55
4.51
4.54
4.51
4.66
4.58
4.53
COOLING ONLY (EN14511 VALUE)
COOLING CAPACITY *1 *2
kW
43.6
52.6
62.7
71.7
83.4
100.0
119.0
129.0
EER *1 *2
2.73
2.75
2.88
2.82
2.82
2.82
2.80
2.72
ESEER *1 *2
4.27
4.19
4.17
4.23
4.24
4.36
4.27
4.25
COOLING ENERGY CLASS
C
C
C
C
C
C
C
C
SEASONAL EFFICIENCY IN COOLING (REG.EU 2016/2281) - AVERAGE CLIMATE CONDITIONS
SEER
4.15
4.11
4.13
4.18
4.23
4.36
4.32
4.30
PERFORMANCE (ƞs)*3
%
163
161
162
164
166
171
170
169
HEAT EXCHANGER (USER SIDE)
WATER FLOW *1
l/s
2.1
2.53
3.02
3.45
4.01
4.82
5.73
6.18
MIN. SYSTEM WATER CONTENT
l
154
185
221
252
293
354
420
452
PRESSURE DROP
kPa
37.2
41.2
42.3
39.4
35
36.2
42.9
38.9
INLET / OUTLET CONNECTION SIZE
in
1 1/2" VICTAULIC
1 1/2" VICTAULIC
1 1/2" VICTAULIC
2" VICTAULIC
2" VICTAULIC
2" VICTAULIC
2 1/2" VICTAULIC
2 1/2" VICTAULIC
REFRIGERANT CIRCUIT
COMPRESSORS
1
2
2
2
2
2
2
2
CIRCUITS
1
1
1
1
1
1
1
1
REGULATION
STEPLESS
STEPLESS
STEPLESS
STEPLESS
STEPLESS
STEPLESS
STEPLESS
STEPLESS
MIN. CAPACITY STEP
%
30
22
19
22
19
23
20
18
REFRIGERANT CHARGE R410A
kg
7
7.2
8.9
9.4
9.5
12.5
12.9
13.5
CO2
EQUIVALENT
t
14.6
15
18.6
19.6
19.8
26.1
26.9
28.2
OIL CHARGE
kg
3.5
6.1
6.4
6.7
7
13.4
13.4
13.4
ELECTRICAL
FULL LOAD POWER (F.L.I.)
kW
23.5
27.4
30.2
37.5
41.4
53.9
59.7
64.6
FULL LOAD CURRENT (F.L.A.)
A
39
46
52
63
70
87
96
104
INRUSH CURRENT (S.A.)
A
4
118
164
174
225
198
243
288
FANS
QUANTITY
4
4
5
5
6
2
2
2
AIRFLOW
m³/s
3.77
5.07
6.57
6.57
7.66
9.08
11.53
11.53
*1 Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C.
FANS POWER INPUT
kW
0.2
0.3
0.3
0.3
0.3
1.2
2
2
*2 Values in compliance with EN14511-3:2013.
*3 Seasonal energy efficiency of space cooling.
NOISE LEVEL
*4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface;
SOUND PRESSURE *4
dB(A)
51
52
53
53
54
55
57
57
non-binding value calculated from the sound power level.
SOUND POWER *5 *6
dB(A)
83
84
85
85
86
87
89
89
*5 Sound power on the basis of measurements made in compliance with ISO 9614.
SIZE AND WEIGHT
*6 Sound power level in cooling, outdoors.
*7 Unit in standard configuration/execution, without optional accessories.
WIDTH *7
mm
2000
2000
2625
2625
2625
3250
3250
3250
DEPTH *7
mm
1350
1350
1350
1350
1350
1350
1350
1350
HEIGHT *7
mm
2070
2070
2070
2070
2070
2170
2170
2170
Eurovent Certified Data
OPERATING WEIGHT *7
kg
600
660
750
780
810
1060
1070
1080
Climaveneta’s range of small to medium sized i-NX Cooling Only chillers efficiently and easily
i-NX
adapt to a wide range of cooling capacities. The super low noise variant offers up to a 7dB(A)
reduction against the baseline model.
Air Cooled Chiller
With the exclusive 1 + i philosophy both the fixed speed scroll compressor and the scroll inverter compressor are combined in the
same circuit. This technology ensures maximum benefit in terms of efficiency at partial loads compared to a solution with separate
Low Noise Version
circuits. In different load conditions, only the most efficient combination of compressors required for optimum adaptation to the
system load conditions is called upon.
(42.6-124kW)
Key Features
High Efficiency - inverter driven scroll compressor
Available with EC fans
Cooling Only
Aluminium microchannel coils
ERP 2021 compliant
Wide operating range
Available with hydronic module
Three Phase
i-NX
i-NX
i-NX
i-NX
i-NX
i-NX
i-NX
i-NX
MODEL
SL 0151P
SL 0182P
SL 0202P
SL 0262P
SL 0302P
SL 0352P
SL 0402P
SL 0502P
POWER SUPPLY
V / ph / Hz
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3+N/50
400/3/50
400/3/50
400/3/50
PERFORMANCE
COOLING CAPACITY *1
kW
42.6
51.2
60.1
68.1
81.2
96.7
115.0
124.0
TOTAL POWER INPUT *1
kW
14.4
17.8
20.9
24.5
28.3
33.9
39.3
44.3
EER *1
2.96
2.88
2.88
2.78
2.87
2.85
2.93
2.81
ESEER *1
4.48
4.58
4.49
4.55
4.54
4.75
4.78
4.7
COOLING ONLY (EN14511 VALUE)
COOLING CAPACITY *1 *2
kW
42.3
50.9
59.8
67.7
80.8
96.3
115.0
124.0
EER *1 *2
2.89
2.81
2.81
2.73
2.82
2.80
2.88
2.76
ESEER *1 *2
4.21
4.26
4.2
4.25
4.26
4.48
4.5
4.43
COOLING ENERGY CLASS
C
C
C
C
C
C
C
C
SEASONAL EFFICIENCY IN COOLING (REG.EU 2016/2281) - AVERAGE CLIMATE CONDITIONS
SEER
4.18
4.10
4.11
4.17
4.22
4.46
4.50
4.48
PERFORMANCE (ƞs)*3
%
164
161
162
164
166
176
177
176
HEAT EXCHANGER (USER SIDE)
WATER FLOW *1
l/s
2.04
2.45
2.87
3.26
3.88
4.62
5.5
5.95
MIN. SYSTEM WATER CONTENT
l
149
179
210
238
284
338
403
434
PRESSURE DROP
kPa
35.1
38.7
38.3
35.2
32.9
33.2
39.6
36.0
INLET / OUTLET CONNECTION SIZE
in
1 1/2" VICTAULIC
1 1/2" VICTAULIC
1 1/2" VICTAULIC
2" VICTAULIC
2" VICTAULIC
2" VICTAULIC
2 1/2" VICTAULIC
2 1/2" VICTAULIC
REFRIGERANT CIRCUIT
COMPRESSORS
1
2
2
2
2
2
2
2
CIRCUITS
1
1
1
1
1
1
1
1
REGULATION
STEPLESS
STEPLESS
STEPLESS
STEPLESS
STEPLESS
STEPLESS
STEPLESS
STEPLESS
MIN. CAPACITY STEP
%
30
23
20
23
20
24
21
19
REFRIGERANT CHARGE R410A
kg
8.1
8.3
8.7
9.2
11.8
12.3
14.7
15.2
CO2
EQUIVALENT
t
16.9
17.3
18.2
19.2
24.6
25.7
30.7
31.7
OIL CHARGE
kg
3.5
6.1
6.4
6.7
7
13.4
13.4
13.4
ELECTRICAL
FULL LOAD POWER (F.L.I.)
kW
23.8
27.4
30.5
37.8
43.6
53.9
59.3
64.3
FULL LOAD CURRENT (F.L.A.)
A
40
47
53
64
71
87
95
104
INRUSH CURRENT (S.A.)
A
6
120
165
175
226
198
242
287
FANS
QUANTITY
5
5
6
6
2
2
2
2
*1 Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C.
AIRFLOW
m³/s
4.28
5.03
5.73
5.73
7.37
8.41
10.47
10.47
*2 Values in compliance with EN14511-3:2013.
FANS POWER INPUT
kW
0.2
0.2
0.2
0.2
0.9
1.1
1.15
1.15
*3 Seasonal energy efficiency of space cooling.
*4 Average sound pressure level at 10m distance, unit in a free field on a reflective surface;
NOISE LEVEL
non-binding value calculated from the sound power level.
SOUND PRESSURE *4
dB(A)
45
45
46
46
47
48
50
50
*5 Sound power on the basis of measurements made in compliance with ISO 9614.
SOUND POWER *5 *6
dB(A)
77
77
78
78
79
80
82
82
*6 Sound power level in cooling, outdoors.
SIZE AND WEIGHT
*7 Unit in standard configuration/execution, without optional accessories.
WIDTH *7
mm
2625
2625
2625
2625
3250
3250
3875
3875
DEPTH *7
mm
1350
1350
1350
1350
1350
1350
1350
1350
HEIGHT *7
mm
2070
2070
2070
2070
2170
2170
2170
2170
Eurovent Certified Data
OPERATING WEIGHT *7
kg
700
760
790
820
980
1090
1180
1200
2.17
Chillers
i-NX Air Cooled Chiller Range